Send inquiry
ST/STC Three phase A. C Electric Synchronous generator
1. 100% Copper wire /50% copper &50% aluminum /100% aluminum
2. OEM service offered
3. Competitive price, good qua
(1)STC generators diesel are to be used in town, the countryside, work sites, mountains and pasture lands as a electric power source for lighting purpose. It can also be used as a reserved power source for emergent case.
(2)The generators are of drip-proof with rotary field type and harmonic excitation system, making use of the star connection with neutral point.
(3)The rated line voltage is 400V; Phase voltage is 230V; Frequency is 50Hz; Power factor is 0.8(lag). We can provide the generator with 60Hz and the other voltage according to request.
(4)They can be coupled with a prime mover directly or through V-belt, rotating right or reverse continuously at the rated speed.
(5)Operating Conditions
Cooling air temperature: -15oC~40oC
Above sea level: Not exceed 1000m
Relative air damping: Not exceed 90%
Technical Data:
1. 100% Copper wire /50% copper &50% aluminum /100% aluminum
2. OEM service offered
3. Competitive price, good qua
(1)STC generators diesel are to be used in town, the countryside, work sites, mountains and pasture lands as a electric power source for lighting purpose. It can also be used as a reserved power source for emergent case.
(2)The generators are of drip-proof with rotary field type and harmonic excitation system, making use of the star connection with neutral point.
(3)The rated line voltage is 400V; Phase voltage is 230V; Frequency is 50Hz; Power factor is 0.8(lag). We can provide the generator with 60Hz and the other voltage according to request.
(4)They can be coupled with a prime mover directly or through V-belt, rotating right or reverse continuously at the rated speed.
(5)Operating Conditions
Cooling air temperature: -15oC~40oC
Above sea level: Not exceed 1000m
Relative air damping: Not exceed 90%
Technical Data:
Model | Output power(KW) | Current(A) | Voltage(V) | Power factor | Pole number | Speed (r/min) | Steady Volt Regulation (%) | ||
Series connection | Parallel connection | Series connection | Parallel connection | ||||||
ST-2 | 2 | 8.7 | 17.4 | 230 | 115 | 1.0 | 4 | 1500 | ±5 |
ST-3 | 3 | 13 | 26 | ||||||
ST-5 | 5 | 21.8 | 43.5 | ||||||
ST-7.5 | 7.5 | 32.6 | 65.2 | ||||||
ST-10 | 10 | 43.7 | 87 | ||||||
ST-12 | 12 | 52.2 | 104.4 | ||||||
ST-15 | 15 | 65.2 | 130.4 | ||||||
ST-20 | 20 | 87 | 174 | ||||||
ST-24 | 24 | 87 | 174 |
Model | Output power(KW) | Rated capacity(KVA) | Rated current(A) | Pole number | Speed (r/min) |
STC-3 | 3 | 3.8 | 5.4 | 4 | 1500 |
STC-5 | 5 | 6.3 | 9 | ||
STC-7.5 | 7.5 | 9.4 | 13.5 | ||
STC-10 | 10 | 12.5 | 18.1 | ||
STC-12 | 12 | 15 | 21.7 | ||
STC-15 | 15 | 18.8 | 27.1 | ||
STC-20 | 20 | 25 | 36.1 | ||
STC-24 | 24 | 30 | 43.3 | ||
STC-30 | 30 | 37.5 | 54.1 | ||
STC-40 | 40 | 50 | 72.2 | ||
STC-50 | 50 | 62.5 | 90.2 | ||
STC-64 | 64 | 80 | 115.4 | ||
STC-75 | 75 | 93.7 | 135.3 |